Granville, Richard and Charlton, Peter (2016) Detection and Sizing of Baffle Plate Erosion and Fretting using Eddy Current Array Technology. ndt.net, 21 (09). ISSN 1435-4934
|
Text
114_Charlton_Rev2.pdf - Published Version Available under License CC-BY-NC-ND Creative Commons Attribution Non-commercial No Derivatives. Download (888kB) | Preview |
Abstract
The paper describes the evaluation of current state of the art Eddy Current Array (ECA) technology used for the detection and sizing of heat exchanger tube baffle plate erosion and fretting type defects. For validation purposes, all defects were also subject to Internal Rotary Inspection System (IRIS) ultrasonic evaluation. Results of the study indicate that a probability of detection (POD) figure of 84.6% is achievable for the ECA method with a probability of sizing (POS) mean measurement error of approximately +6.9% when compared to the IRIS sizing results.